CCB/CCR SEMI-HERMETIC

2 to 6 semi-hermetic Copeland STREAM 4 and 6 cylinders (4M and 6M) Designed to be installed directly in technical room.

Application: CC B : Low temperature R404A and R407F. Evaporating temperature -40°C to -25°C.

CC R : Medium temperature R404A, R134a and R407F. Evaporating temperature -15°C to -5°C.

CC H : High temperature R404A and R407F. Evaporating temperature -5°C to +5°C. CC H : High temperature R134a. Evaporating temperature -10°C to +10°C.

Compressor pack system are designed for maximum operating pressures: PS(LP)=17 bar and PS(HP)=28 bar for R404A/R407F PS(LP)=15 bar and PS(HP)=19 bar for R134a. Pack with total EC marked. Conform to PED 97/23/CE.

  • Valves on suction and discharge, oil sightglass, crankcase heater.
  • Copeland semi-hermetic compressors, suction gas cooled.
  • STREAM typefor compressors 4 and 6 cylinders (4M and 6M).
  • 3 phase motor-400 V – direct start. CoreSense Diagnostics module for compressors STREAM (combining motor and oil protections. In addition it provides advanced protection such as high discharge temperature, locked rotor, single/ missing phase, voltage imbalance and low voltage protection. The module is capable of communication via Modbus® protocol.
  • Copper header.
  • Oil separator with removable float and oil pre-charge.
  • Isolating valve on discharge
  • Oil level regulators with float and hand valve on each compressor.
  • 7 liters (2,3 and 4 compressors), 14 liters (5 and 6 compressors) oil receiver with level sight glasses, shut-off valves, differential valve degassing in the section header set to 1.4 bar, sightglass and filter on oil inlet.
  • Connections by flexible hoses (separator, receiver, regulators).
  • 1 or more cartridge filters with schrader valve.
  • 1 or more return lines with valves.
  • Copper header until 3’’1/8 and 304L stainless steel beyond.
  • HP pressure switch non-adjustable by compressor.
  • LP adjustable pressure switch by compressor.
  • Connections by flexible hoses.
  • CoreSense (Oil pressure switch integrated).
  • Remote vertical type receiver, fitted with shut off valve on inlet and outlet, safety pressure relief valve: single or double according to the volume.
  • Liquid station fitted with filter drier with:
    • Replaceable cartridge
    • Filling valve 3/8’’ flare
    • Stop valves before / after the cartridge
    • Hygroscopic sightglass, shut-off valve on outlet